Specification: | |||
All specification are typical at nominal input, full load at 25 degrees C otherwise stated. | |||
INPUT | Input Voltage Range | 160Vac~290Vac | |
Input Frequency (Hz) | 47Hz~63Hz | ||
Rated Input Voltage | 220Vac | ||
Efficiency (%) | 81% typ | ||
Inrush Current | <50A | ||
Input Current | <1.4A | ||
OUTPUT | Output Voltage | V+/BAT+ | |
6V/12V/36/72V | |||
Load Current | 1A TO 10A | ||
Line Regulation | <±0.5% | ||
Load Regulation | <±5.0% | ||
Over Load Protection | 108%~135%,Constant Current | ||
Short Circuit Protection | YES | ||
Reverse Battery Protection(When SMPS use as a charger) | BAT+ without output | ||
Primary to Secondary | 1.5KVAC/min, Cutoff current<10mA | ||
Primary to P.G | 1.5KVAC/min, Cutoff current<10mA | ||
Secondary to P.G | 0.5KVDC/min, Cutoff current<10mA | ||
PROTECTION
FUNCTION |
Primary to Secondary | >100MΩ | |
Primary to P.G | >100MΩ | ||
Secondary to P.G | >100MΩ | ||
LED INDICATION | Dimensions(L*W*H) | 11X12 INCH | |
Cooling method | free air convection | ||
Operating temperature & humidity | 0℃~45℃, 20%~90% RH | ||
ISOLATION | Storage temperature & humidity | -10℃~55℃, 10%~95% RH | |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. |
* Two options for user: | |||
* 1. connect to V+/V-,it is a normal SMPS | |||
* 2. connect to BAT+/BAT-,it is used as a battery charger | |||
* Protections:OLP/SCP/RBP | |||
* High efficiency; High reliability. | |||
* 100%full load burn-in test; | |||
Specification: | |||
All specification are typical at nominal input, full load at 25 degrees C otherwise stated. | |||
INPUT | Input Voltage Range | 160Vac~290Vac | |
Input Frequency (Hz) | 47Hz~63Hz | ||
Rated Input Voltage | 220Vac | ||
Efficiency (%) | 81% typ | ||
Inrush Current | <50A | ||
Input Current | <1.4A | ||
OUTPUT | Output Voltage | V+/BAT+ | |
+12V | |||
Load Current | 10A | ||
Line Regulation | <±0.5% | ||
Load Regulation | <±5.0% | ||
Ripple & Noise (mVp-p) | 0~20MHz | <120mVP-P | |
Temperature coefficient | <0.03%/℃ | ||
Adjusted Voltage | 11.40V~13.80V | ||
Start-up Time | <1.0S | ||
Hold-up Time | > 20mS | ||
Output Power | 102Wtyp | ||
PROTECTION
FUNCTION |
Over Load Protection | 108%~135%,Constant Current | |
Short Circuit Protection | Shut Down | ||
Reverse Battery Protection(When SMPS use as a charger) | BAT+ without output | ||
LED INDICATION | S-PG | Power Good Indication | |
S-OL | Over Load Indication | ||
S-RB | Reverse Battery Indication | ||
ISOLATION | Primary to Secondary | 1.5KVAC/min, Cutoff current<10mA | |
Primary to P.G | 1.5KVAC/min, Cutoff current<10mA | ||
Secondary to P.G | 0.5KVDC/min, Cutoff current<10mA | ||
ISOLATION
RESISTANCE |
Primary to Secondary | >100MΩ | |
Primary to P.G | >100MΩ | ||
Secondary to P.G | >100MΩ | ||
STRUCTURE | Dimensions(L*W*H) | 199×98×40 (mm) | |
Cooling method | free air convection | ||
ENVIRONMENT | Operating temperature & humidity | 0℃~45℃, 20%~90% RH | |
Storage temperature & humidity | -10℃~55℃, 10%~95% RH | ||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. | ||
2. Ripple& noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uF &47uF | |||
parallel capacitor . | |||
3. Tolerance: includes set up tolerance, line regulation and load regulation . | |||
4 .LVLD(if the battery voltage is lower than 8.1Vdc,the SMPS don’t charge the battery) |